    Limitation of RCCB. Standard electromechanical RCCBs are designed to operate on normal supply waveforms and cannot be guaranteed to operate where none standard waveforms are generated by loads. The most common is the half wave rectified waveform sometimes called pulsating dc generated by speed control devices, semi conductors, computers and even dimmers. Specially modified RCCBs are available which will operate on normal ac and pulsating dc. RCDs don’t offer protection against current overloads: RCDs detect an imbalance in the live and neutral currents. A current overload, however large, cannot be detected.

    It is a frequent cause of problems with novices to replace an MCB in a fuse box with an RCD. This may be done in an attempt to increase shock protection. If a live-neutral fault occurs (a short circuit, or an overload), the RCD won’t trip, and may be damaged. In practice, the main MCB for the premises will probably trip, or the service fuse, so the situation is unlikely to lead to catastrophe; but it may be inconvenient. It is now possible to get an MCB and and RCD in a single unit, called an RCBO (see below). Replacing an MCB with an RCBO of the same rating is generally safe.

    Nuisance tripping of RCCB: Sudden changes in electrical load can cause a small, brief current flow to earth, especially in old appliances. RCDs are very sensitive and operate very quickly; they may well trip when the motor of an old freezer switches off. Some equipment is notoriously `leaky’, that is, generate a small, constant current flow to earth.

    Pdf Difference Between Mccb Mcb Rccb And Elcb

    Some types of computer equipment, and large television sets, are widely reported to cause problems. RCD will not protect against a socket outlet being wired with its live and neutral terminals the wrong way round. RCD will not protect against the overheating that results when conductors are not properly screwed into their terminals. RCD will not protect against live-neutral shocks, because the current in the live and neutral is balanced. Your Maths seems to be in error’.

    Ohms law is (voltage / resistance) not as you have it “500ohms / 230volts”see the below extract from your text:Quote ” The safest limit of Current which Human Body can withstand is 30mA sec.Suppose Human Body Resistance is 500Ω and Voltage to ground is 230 Volt.The Body current will be 500/230=460mA.Hence ELCB must be operated in 30mASec/460mA = 65msec”Hope you are able to revise accordinglyit strange how so many people missed this error. On such a basic principle. Hi i am a certified electrical inspector engineer and i have a testing instrument to check RCB according to IEC procedure. All installations have to be checked by this type of instrument at least every 5 years for normal housings and once a year for industrial and public places. Some public places are even compelled by law to check twicw a year.

    You shall be surprised of how many RCB i find out of range after 4 to 5 yearsaccording to manufactyrers instructions the test button MUST be pushed once a month. The RCB mechanical system tends to get stuck if not actuated for a long period. Dear Jigneshbhai,I stay at Mangalore and I am a layman as far as Electricity is concerned, earlier I was staying at Ahmedabad where the electricity was of good quality.

    Your article was very informative.Here in Mangalore many times I have noticed that after a power outage when the power returns, there is current in the neutral line. It may be due to faulty re-connection by the electricity linesman. At this time if any appliance is on, it gets fried, also we get a shock on touching the appliance. Some of my appliances were destroyed because of this.

    I would like to know if I can use Residual circuit device(RCD) to prevent damage to appliances or will a 3 pin adapter with fuse will help. Or is there any other device that can help prevent damage to appliances when there is current in Neutral( as tested with a screw driver tester).

    Power outage occurs here at least 3 times a day!!Thanks in advance. RCDs detect an imbalance in the live and neutral currents. A current overload, however large, cannot be detected. It is a frequent cause of problems with novices to replace an MCB in a fuse box with an RCD. This may be done in an attempt to increase shock protection.

    If a live-neutral fault occurs (a short circuit, or an overload), the RCD won’t trip, and may be damaged. In practice, the main MCB for the premises will probably trip, or the service fuse, so the situation is unlikely to lead to catastrophe; but it may be inconvenient.It is now possible to get an MCB and and RCD in a single unit, called an RCBO (see below). Replacing an MCB with an RCBO of the same rating is generally safe. The RCCB will operate and cut off supply to the load if there is an unbalance (or difference) in the currents flowing thru the Phase (Line or Live) wire and the Neutral wire. In the Malaysian system, all equipment and utensils ( esp. Those made of metal), the body or casing is connected to an Earth wire, which originates from the Main Switch Board. In the unlikely event of the Phase wire coming into contact with the body of the appliance (e.g.

    A bread toaster), a leakage current will flow from the body of the appliance to Earth, causing an unbalance in the RCCB and forcing it to trip and isolate the load.If an Earth wire system is not provided, the RCCB will trip only when a human touches the appliance, causing a current to flow thru him to Earth or Ground, resulting in an unbalance in the RCCB. An efficient RCCB needs to be sensitive to about 30mA leakage current and operate fast enough to avoid any hazard to the human.Am I right? I believe this is not dangerous as when we use a Test Pen on the Phase wire, a small current does flow thru our body to Earth causing the lamp to light.The doubt is whether the current thru our is the same in both instances.Thank you and hoping for some clarification on this matter. Thank u v.much Sir.

    I’ve few doubts. V r constructing a 2BHK house in Chennai. Can i re-use a 4yr old (was working) 40A AUTO PHASE CHANGER? I also have 25A Rotary phase changers (say RPC) in a box, and in same DB box, 12 LeGrand MCBs (2x c20,4x c16, 2x c10, 4x c6) r there.Shall i connect 3 parts/places(AC1, AC2, & Kitchen) to these RPCs via 63A RCCB in DB & again take back to DB & connect with MCBs?!! So that i can connect confidently all remaining divisions with AUTO-PHASE CHANGER.Also i’ll be glad if i get a chance to talk with you rgdg it. Am not comfortable in txtingThank uSankar TL.

    Hi Jignesh I was following through ur various posts on meter bypass. I have a scenario on which I would like ur valuable expert comments. I live in a multi storied government quarter. I would like to know how to bypass the single phase electronic meter. It is giving me sleepless nights.

    Presently both the live and the neutral from the meter goes to a MCCB which then terminates in our flats DP.One option I am considering is like using 2 wires from one live phase from main connection. One goes through the meter and other directly to the house. Since distance from the meter to our house is considerable I cannot discreetly lay a new line to the flat I plan to disconnect the neutral in the MCCB and connect the unmetered live wire to the neutral port of the MCCB. In this way 2 wires both having the same phase would be coming to my flat from a single MCCB.

    We have 2 separate earth connections to the flat. For neutral I plan to use the earth wire. The second earth will be used for the three pin connections so that they are secured. The metered live phase could be used for some very low load to ensure meter running for atleast the minimum units. The unmetered phase will be used for rest of the loads. My query is-1) Will the MCCB allow 2 live connections through it (both would of same phase so no 440 volts chance)?2) Can I install a MCB with the earth which I would using as neutral.

    IF so, of how much rating.3) What safety precautions should I take for preventing electrical shocks and equipment safety.Pse reply fast.With regards. @Meter Manageranswers to your query:1) don’t even try to do that.

    You can’t connect 2 feeder cables to one MCCB. One of the resons is electric shock at the start point of cable although its feeding circuit breaker is disconnected. But, you can connect 2 cables from MCCB and supply 2 or more consumers.2) you can’t do that neither. If there is a RCD it will trip in that case, and earth conducter must not carry current in normal regime, only in case of fault.3) use appropriate protection (MCB, MCCB, RCD, RCBO, etc), cable sizing to match equipment needs, and use of appropriate IP rating for environment where equipment is installed.

    . Related Post:Difference between IEC 60898-1 and IEC 60947-2 IEC60898-1It defines behavior of circuit breaker having rated operational voltage not exceeding than 440V (between Phases), Rated current not exceeding than 125A (We have range 0.5A-125A) and rated short circuit capacity not exceeding than 25KA ( Usually it is 10KAin MCB). This is designed for unskilled user (or say uninstructed user) and for devices not being maintained consequently. Also pollution degree covered is zero pollution to maximum pollution (degree 2). These are the circuit breakers we find in residential homes, shops, school & offices electrical distribution switchboards. Related Post:IEC60947-2This standard applies to circuit-breakers, the main contacts of which are intended to be connected to circuits, the rated voltage of which does not exceed 1000 V a.c. Or 1500 V d.c.; it also contains additional requirements for integrally fused circuit-breakers.

    It covers very high range of standard current carrying capacity (We have range of 6A-6300A) and meant for skilled user. The device is also supposed to be maintained properly. Also pollution degree is to be 3 or more. These circuit breakers are industrial applications and protect the power distribution of up to 1000 volts AC. And 1500 volts DC. (For MCBs, MCCBs & ACBs).

    Comparison Between IEC 69896-1 & IEC 60947-2 MCB CharacteristicIEC 60898-1IEC 60947-2Rated Current: In6 – 125A0.5 – 160ASC Breaking Capacity. I CS as a% from I CU. (See Difference between I CS & I CU in term of Circuit Breakers). Maximum Operating Voltage. Insulation voltage. Mechanical operation ( endurance and durability). Breaking Capacity for each Operating VoltageBelow are types of MCBs which shows the magnetic fault protection.

    Also, to prevent the accidental overloading of the cable at no fault, there is a thermal device in MCB to eliminate the chances of unwanted tripping operation of MCB. For short circuit protection in home appliances, the current rating is about to 6kA while for heavy and industrial operation, it is above the 10kA. Characteristic of MCB and FUSE. Both MCB and rated in Amperes which is known as Nominal Current or Rated Current. Keep in mind that an MCB or Fuse with rated current of 50A will not trip when current of more than 50A is flowing through it.

    The reason is that MCB and Fuse with same rated current has different properties. For a 63A MCB and 60A Fuse where it should trip in 0.2 sec, MCB will trip at 260A and fuse will trip at 600A. It shows Fuse delay is very high as compared to MCB. Sometimes, fuse blow itself without a reason. It may be due to the previous overloads for specific time which has not been noticed.

    In case of Fuse, if the rated current is 60A, it will carry up to 80A for an hour or two. This is the same like modern PVC cables hold 50% overload for an hour.

    A previous post can be read for more details under the title of “Main “What is ELCB (Earth Leakage Circuit Breaker)ELCB stands for “ Earth Leakage Circuit Breaker” and it is used for protecting a person from electric shock and injury. The needs of these devices arise because of the number increasing in injuries as well as deaths because of electric shock. This device is invented almost 50 years ago, but nowadays ELCB is not suitable because of its some disadvantages hence another device RCB (Residual circuit breaker) or RCD (Residual Current Devices) whose functionality is same with more advantages, but theory of operation is entirely different from ELCB.

    Some of ELCB characteristic are as follow. It is international standard that each electronics device enclosure should be earthed. So, there would be no chance of electrocutions. For proper operation of ELCB, its need to bury a metallic rod deep in the soil and ELCB is connected between the wire coming from the rod to the wire attached to the external metallic body of the Electrical device or you can say that ELCB is connected to the Earth wire.

    ELCB Operation:When the live wire (accidentally) touches the metallic body of the connected device or appliance, then there is potential generated between the earthed rod and the metallic enclosure of that device. The circuitry (inside the ELCB) senses the potential difference and when this potential difference reached at 50volt then ELCB cuts off the main supply from the connected device. This way it ensures the safety of the human beings. Without proper earth connection, ELCB will not work. If the wire attached to the earthed rode is loose or broken, then ELCB would not able to sense the potential hazardous voltage on the metallic body of the electrical/electronic device. ELCB is attached between earthed wire and metallic body of the electrical appliances.

    But there are many other parallel paths for the currents to flow from the connected device body to earth without going through earthed wire. There are many metallic pipes in the house, which can provide a parallel path for the current to flow towards the earth. In this way, sometime ELCB is not able to detect the hazardous voltage on the metallic body of the device, which may cause serious injury. If someone gets in touch with live phase wire, ELCB will not Trip because in this case, there will be no current flow in the earth wire. In fact, current is flowing from the live wire to earth through the person’s body. When a live wire comes in contact with neutral wire, short circuit will occur, hence, ELCB will not trip because there will be no current in the earth wire. There are many cases in which, there is a current flow in the earth wire, but the situation is not hazardous in such cases, but it gives false trip e.g.

    Lightening strike, current starts flowing in the earth wire and ELCB trips.To overcome with the above disadvantages of ELCB, another Device named Residual Current Breaker (RCB) is invented to use for earth leakage protection. Most widely used RCD is 30mA to 10mA. 300 to 500mA RCCB are used for such as in lighting circuits with little chances of electric shock.

    Line (Phase or Live) and Neutral (N) both wires are connected to the load points through RCCB (RCD). RCD operate and trip when there is an earth fault current in the circuit. The same amount of current should flows through Neutral Wire as current flows in Live (Phase) wire i.e. Equal current should flows in both Phase and Neutral Wire. If RCD detect unequal current (Phase and Neutral Current should be same as mentioned above) in phase or neutral wire, it will trip the circuit and disconnect the load points in 30m sec. RCD devices are very effective for electric shock protection.

    In a home where is connected only to and not to the main incoming supply cables, all circuits must be protected by an RCD otherwise, MCB might not get the specified fault current which is important to trip the MCB from connected circuits. The polarity of the phase winding and the neutral winding is opposite in normal condition. Therefore, EMF generated by the phase wire cancels out by the EMF of the neutral wire.

    If there is a difference in the incoming and outgoing currents, then the resultant EMF will not be zero and can be sensed by the CT of RCB. The signal from the RCB is fed to the RCB circuit and it opens the main power contacts. Advantages of RCD:.

    If there is no connection between the ground and the enclosure of the device, and a person touches the metallic body of that device. In this case, incoming and outgoing current will be different and RCB will Trip in contrast with ELCB. Functionality of RCB (Residual Current Breaker) does not effect by lightning strikes. It does not trip falsely.Related Post.

    Disadvantages of RCD:. RCD don’t provide protection against Current Overload.

    But the main MCB will trip the circuit as RCCD won’t trip in case of a live or neutral faults i.e. Short circuit and overload. For this reason, RCBO (MCB with RCD in a single unit) are used for proper protection. It operates only on normal supply i.e. It will not detect the pulsating DC and half wave rectified waveform.

    For these reason, special RCCB are used which is also operating on rectified pulsating DC voltage. Annoyance operation of RCD in case of sudden changes in load current. RCDs are very sensitive and operate on even a very small amount of faulty current very quickly.

    In case of switching of old electrical appliances, there is a small constant current flow through earth which lead to trip the circuit. RCD will not protect against overheating, Live – Neutral Shocks, and Socket outlet being wired with its Live & Neutral Terminals.RCBO (Residual Circuit Breaker with Overload)As we know that RCD won’t provide protection against Overload, hence an MCB and RCD are presented in a single unit known as RCBO (Residual Circuit Breaker with Overload). The operating principles are same as above but it provide more and reliable operation with overload protection in single box. Related Post:Difference between ELCB and RCCB CharacteristicELCBRCCB (Also known as RCD or RCB)AbbreviationEarth Leakage Circuit BreakerResidual Current Circuit BreakerOperationVoltage Operated Device (Old Name, Old Technology).Current Operated Device (New Name, New Technology).Fault DetectionOnly detects earth faults that flow back through the main earth wire.It will detect any earth fault. That’s why they are using now instead of ELCB.ConnectionConnected to Phase, Neutral as well as Earth Wire.It is only connected to Phase and Neutral Wire.InstallationNeeds an earth connection itself.No need of earth connection.Types. AC = used for Alternating Current. A = Used for Square-wave.

    B = Used to DC. AC = Used for Alternating Current. A = Used for Square-wave. B = Used to DCNuisance TrippingLessHighCostCostlyLess CostApplicationsNot recommended. Replace it with RCCD.Almost all wiring systems use RCCD nowadays.Keep in mind that both ELCB and RCCB are used for the same purpose but wiring connection is different i.e.

    Difference Between Elcb And Rccb Pdf

    In RCCB, only phase and neutral wire should be connected through it whereas in ELCB, main earth wire is connected through it. Hi,As a panel builder and MCB / MCCB / ACB expert I feel obliged to tell you that your explanation of Icu and Ics is the wrong way around.Ics = service is O-t-CO according 60898-1 and O-t-CO-t-CO according 60947-2 and after that 25% of normal lifespan operations on In is still possible.Icu = Ultimate. For 60898-1: Ics=Icu.

    For 60947-2: Icu tested O-t-CO. The max current the breaker can clear for once, after that may need to be replaced. The “no damage” means to circuits and environment.You may read about this in 2CSC0 page 2/2 (pdf: page 8) and other, most important: get familiar with the standards and terms.Kind regards.